《电流电压指针仪表校验报告.docx》由会员分享,可在线阅读,更多相关《电流电压指针仪表校验报告.docx(19页珍藏版)》请在第一文库网上搜索。
1、珠江电厂#3机仪表校验报告仪表名称交流电压表安装地点#3机除灰IIa段#9E母线PT仪表铭牌型号变比量程(V)精确等级编号创造厂7211380/IOOV4501.510391德表校验记录校验点(V)标准示值(V)实测示值上升值(V)误差(船下降值(V)误差()00.000.000.000.000.0015039.4740.650.9940.500.8730078.9580.120.9879.950.84380100.00100.050.04100.090.08450118.42118.570.12118.570.13校验人廖海滔王汉城校验时间2023.2.28仪表名称A相交流电流表安装地点#3
2、机除灰IIa段#9一D空压机动力配电箱仪表铭牌型号变比量程(A)精确等级编号创造厂7211300/5A3001.56296德表校验记录校验点(A)标准不值(A)实测示值上升值(A)误差魏)下降值(A)误差(%)00.000.000.000.000.001001.6671.6890.441.6820.302003.3333.3380.103.3340.023005.0004.997-0.064.997-0.06校验人廖海滔王汉城校验时间2023.2.28珠江电厂#3机仪表校验报告仪表名称B相交流电流表安装地点#3机除灰IIa段#9一D空压机动力配电箱仪表铭牌型号变比量程(A)精确等级编号创造厂7
3、211300/5A3001.58340德表校验记录校验点(A)标准示值(A)实测示值上升值(A)误差(%)下降值(A)误差(%)O0.0000.0000.000.000.00IOO1.6671.6880.421.7010.682003.3333.3760.863.3620.583005.0005.0230.465.0230.46校验人廖海滔王汉城校验时间2023.2.28仪表名称C相交流电流表安装地点#3机除灰IIa段#9一D空压机动力配电箱仪表铭牌型号变比量程(A)精确等级编号创造厂7211300/5A3001.58329德表校验记录校验点(A)标准示值(A)实测示值上升值(A)误差(%)下
4、降值(A)误差闾00.0000.0000.000.0000.001001.6671.6870.401.6900.462003.3333.3520.443.3480.303005.0005.0310.625.0310.62校验人廖海滔王汉城校验时间2023.2.28珠江电厂#3机仪表校验报告仪表名称A相交流电流表安装地点#3机除灰IIa段#9C除灰#3干燥器仪表铭牌型号变比量程(A)精确等级编号创造厂721150/5A501.55834德表校验记录校验点(A)标准示值(A)实测示值上升值(A)误差(%)下降值(A)误差(%)O00.0000.000.0000.001011.0190.0381.0
5、230.462022.0470.942.0320.643033.0450.903.0420.844044.0370.744.0230.465054.997-0.064.997-0.06校验人廖海滔王汉城校验时间2023.2.28珠江电厂#3机仪表校验报告仪表名称B相交流电流表安装地点#3机除灰IIa段#9C除灰#3干燥器仪表铭牌型号变比量程(A)精确等级编号创造厂721150/5A501.55829德表校验记录校验点(A)标准示值(A)实测示值上升值(A)误差(%)下降值(A)误差(%)O00.0000.000.0000.001011.0511.021.0410.822022.0450.902
6、.0501.003033.0370.743.0450.904044.0170.344.0230.465054.997-0.064.997-0.06校验人廖海滔王汉城校验时间2023.2.28珠江电厂#3机仪表校验报告仪表名称C相交流电流表安装地点#3机除灰IIa段#9C除灰#3干燥器仪表铭牌型号变比量程(A)精确等级编号创造厂721150/5A501.56056德表校验记录校验点(A)标准示值(A)实测示值上升值(A)误差(%)下降值(A)误差(%)O00.0000.000.0000.001011.0381.0452022.0682.0523033.0623.0774044.0484.0385
7、055.0205.018校验人廖海滔王汉城校验时间2023.2.28珠江电厂#3机仪表校验报告仪表名称A相交流电流表安装地点#3机除灰IIa段#9B除灰#2干燥器仪表铭牌型号变比量程(A)精确等级编号创造厂721150/5A501.55818德表校验记录校验点(A)标准示值(A)实测示值上升值(A)误差(%)下降值(A)误差(%)O00.0000.000.0000.001011.0380.761.0440.882022.0380.762.0350.703033.0220.443.0190.344044.0270.544.0220.445055.0070.145.0070.14校验人廖海滔王汉城
8、校验时间2023.2.28珠江电厂#3机仪表校验报告仪表名称B相交流电流表安装地点#3机除灰IIa段#9B除灰#2干燥器仪表铭牌型号变比量程(A)精确等级编号创造厂721150/5A501.55553德表校验记录校验点(A)标准示值(A)实测示值上升值(A)误差(%)下降值(A)误差(%)O00.0000.000.0000.001011.0280.561.0320.642022.0470.942.0501.003033.0370.743.0420.844044.0170.344.0200.405055.0140.285.0140.28校验人廖海滔王汉城校验时间2023.2.28珠江电厂#3机仪
9、表校验报告仪表名称C相交流电流表安装地点#3机除灰IIa段#9B除灰#2干燥器仪表铭牌型号变比量程(A)精确等级编号创造厂721150/5A501.55564德表校验记录校验点(A)标准示值(A)实测示值上升值(A)误差(%)下降值(A)误差(%)O00.0000.000.0000.001011.0450.901.0501.002022.0450.902.0420.843033.0310.623.0350.704044.0250.504.0220.445055.0120.245.0120.24校验人廖海滔王汉城校验时间2023.2.28珠江电厂#3机仪表校验报告仪表名称A相交流电流表安装地点#
10、3机除灰IIa段#9A除灰#1干燥器仪表铭牌型号变比量程(A)精确等级编号创造厂721150/5A501.55556德表校验记录校验点(A)标准示值(A)实测示值上升值(A)误差(%)下降值(A)误差(%)O00.0000.000.0000.001011.0380.761.0350.702022.0450.902.0400.803033.0350.723.0390.784044.0270.544.0230.465055.0170.345.0170.34校验人廖海滔王汉城校验时间2023.2.28珠江电厂#3机仪表校验报告仪表名称B相交流电流表安装地点#3机除灰IIa段#9A除灰#1干燥器仪表铭
11、牌型号变比量程(A)精确等级编号创造厂721150/5A501.55823德表校验记录校验点(A)标准示值(A)实测示值上升值(A)误差(%)下降值(A)误差(%)000.0000.000.0000.001010.999-0.020.992-0.162022.0280.562.0300.603033.0270.543.0210.424044.0170.344.0180.365055.0160.325.0160.32校验人廖海滔王汉城校验时间2023.2.28珠江电厂#3机仪表校验报告仪表名称A相交流电流表安装地点#3机除灰IIa段#13A#3除灰动力箱仪表铭牌型号变比量程(A)精确等级编号创造厂7211100/5A1001.55454德表校验记录校验点(A)标准示值(A)实测示值上升值(A)误差(%)下降值(A)误差(%)O00.0000.000.0000.002011.0190.38