《二次退火后再次绞制5.docx》由会员分享,可在线阅读,更多相关《二次退火后再次绞制5.docx(4页珍藏版)》请在第一文库网上搜索。
1、2010年7月份广东远光电缆实业有限公司ACSS/TW-400/50产品试制数据(绞制后)序号实测电阻室内温度eC重量g长度m横截面积mm2拉斯力N强度MPa伸长率%绞制后电阻率Q.mm?/m绞制后相对IACS值10.3039X10226.17.020.2799.308777183200.02761562.4%20.3004X10226.17.130.2839.320978784240.02733363.1%30.2998X10225.97.570.2989.398076982260.02752562.6%40.2995X1O225.57.700.3049.370779485230.02746
2、162.8%50.3056IO226.37.680.3099.195178285200.02741062.9%60.300410225.07.420.2949.337178884210.02749962.7%70.3029X10225.26.650.2689.180076383220.02724063.3%80.2969X10224.97.120.2819.374177282260.02729763.2%90.3027X1O225.47.450.2979.280178484210.02749762.7%100.3020X10226.57.510.2979.354976682260.027536
3、62.6%110.3025IO225.68.040.3219.266377183230.02741662.9%120.308210225.07.310.2979.105774482230.02751462.7%130.3008X1O225.07.480.2979.317576282260.02747762.7%140.3016X10224.97.460.2989.261477283230.02739562.9%150.3040X10225.17.350.2959.217677784230.02746162.8%160.301110225.97.450.2959.343077583270.027
4、48362.7%170.2988X1O225.07.480.2959.380780085260.02748062.7%180.3095X1O225.97.130.2899.127476083-0.02759862.5%注:178为外层数据,19-33为中间层数据,34-43为内层数据。其中外层与内层经过二次退火(第一次外层伸长率不够),退火温度为35(C,保温时间为15Ornin2010年7月份广东远光电缆实业有限公司ACSS/TW-400/50产品试制数据(绞制后)序号实测电阻室内温度eC重量g长度m横截面积mm2拉斯力N强度MPa伸长率%绞制后电阻率Q.mm?/m绞制后相对IACS值190
5、.3232X10228.07.100.3018.726669980250.02733063.1%200.3254X10227.67.010.300&644771082290.02730063.2%210.3196X10227.47.100.2988.814572983240.02736163.0%220.3196X10224.67.060.2988.764871481310.02750662.7%230.3190X10227.07.220.3058.757771982310.2717663.4%240.3195X10227.27.110.2988.826974685300.02741262.9
6、%250.3199X10227.97.030.2948.846372582260.02743262.8%260.3218X10225.67.090.3008.743470681290.02752062.6%270.3200X10224.77.090.2998.772670881280.02755462.6%280.3192X1O226.47.130.3008.792773784240.02736663.0%290.320410226.97.300.3078.797171982280.02742962.9%300.324710224.77.010.3008.644770181270.027551
7、62.6%310.3185X10224.57.020.2978.744570080240.02735963.0%320.3153X10224.77.100.2998.785076787340.02718863.4%330.3180X10224.77.060.2978.794371681300.02745062.8%注:178为外层数据,19-33为中间层数据,34-43为内层数据。其中外层与内层经过二次退火(第一次外层伸长率不够),退火温度为35CrC,保温时间为15Omin。2010年7月份广东远光电缆实业有限公司ACSS/TW-400/50产品试制数据(绞制后)序号实测电阻室内温度C重量g
8、长度m横截面积J)j拉斯力N强度MPa伸长率%绞制后电阻率.mm2m绞制后相对IAeS值340.3090IO228.97.250.2949.123174982280.02722163.3%350.3121X10229.67.130.2929.033674683270.02715163.5%360.3271X1O228.27.060.2938.914475284250.02823361.1%370.3144X10229.27.220.2959.054676184240.02745762.8%380.3055X1O229.87.330.2939.255378985270.02720863.4%39
9、0.314110229.67.140.2948.984776685300.02717763.4%400.332710228.86.880.2988.541374087220.02745162.8%410.3154X1O229.67.310.3009.014776785260.02738163.0%420.3194X10228.37.120.2988.839372182280.02732663.1%430.3166X10229.67.090.2958.891675385290.02711063.6%注:178为外层数据,19-33为中间层数据,34-43为内层数据。其中外层与内层经过二次退火(第
10、一次外层伸长率不够),退火温度为350,保温时间为15Omin。2010年7月份广东远光电缆实业有限公司ACSS/TW-400/50产品试制数据(绞制后)序号实测电阻室内温度9C重量S长度m横截面积mm2拉斯力N强度MPa伸长率%绞制后电阻率C.mm7m绞制后相对IACS值10.2983X10221.46.3700.2559.2417一一0.02741562.9%20.2935X10221.46.2820.2489.37130.02735263.0%30.2960X10221.45.5360.2209.30950.02740362.9%40.2972X1O221.26.4480.2579.28210.02745562.8%注:1:178为外层数据,19-33为中间层数据,34-43为内层数据。其中外层与内层经过二次退火(第一次外层伸长率不够),退火温度为350,保温时间为15OminII2:外层电阻率复检4根。